- 2009-03-24 (火) 19:00
- Windows Server 2008
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\virtualization")
Set colItems = objWMIService.ExecQuery( _
"SELECT * FROM Msvm_HeartbeatComponent",,48)
For Each objItem in colItems
Wscript.Echo "-----------------------------------"
Wscript.Echo "Msvm_HeartbeatComponent instance"
Wscript.Echo "-----------------------------------"
If isNull(objItem.AdditionalAvailability) Then
Wscript.Echo "AdditionalAvailability: "
Else
Wscript.Echo "AdditionalAvailability: " & Join(objItem.AdditionalAvailability, ",")
End If
Wscript.Echo "Availability: " & objItem.Availability
Wscript.Echo "Caption: " & objItem.Caption
Wscript.Echo "CreationClassName: " & objItem.CreationClassName
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "DeviceID: " & objItem.DeviceID
Wscript.Echo "ElementName: " & objItem.ElementName
Wscript.Echo "EnabledDefault: " & objItem.EnabledDefault
Wscript.Echo "EnabledState: " & objItem.EnabledState
Wscript.Echo "ErrorCleared: " & objItem.ErrorCleared
Wscript.Echo "ErrorDescription: " & objItem.ErrorDescription
Wscript.Echo "HealthState: " & objItem.HealthState
If isNull(objItem.IdentifyingDescriptions) Then
Wscript.Echo "IdentifyingDescriptions: "
Else
Wscript.Echo "IdentifyingDescriptions: " & Join(objItem.IdentifyingDescriptions, ",")
End If
Wscript.Echo "InstallDate: " & objItem.InstallDate
Wscript.Echo "LastErrorCode: " & objItem.LastErrorCode
Wscript.Echo "LocationIndicator: " & objItem.LocationIndicator
Wscript.Echo "MaxQuiesceTime: " & objItem.MaxQuiesceTime
Wscript.Echo "Name: " & objItem.Name
If isNull(objItem.OperationalStatus) Then
Wscript.Echo "OperationalStatus: "
Else
Wscript.Echo "OperationalStatus: " & Join(objItem.OperationalStatus, ",")
End If
Wscript.Echo "OtherEnabledState: " & objItem.OtherEnabledState
If isNull(objItem.OtherIdentifyingInfo) Then
Wscript.Echo "OtherIdentifyingInfo: "
Else
Wscript.Echo "OtherIdentifyingInfo: " & Join(objItem.OtherIdentifyingInfo, ",")
End If
If isNull(objItem.PowerManagementCapabilities) Then
Wscript.Echo "PowerManagementCapabilities: "
Else
Wscript.Echo "PowerManagementCapabilities: " & Join(objItem.PowerManagementCapabilities, ",")
End If
Wscript.Echo "PowerManagementSupported: " & objItem.PowerManagementSupported
Wscript.Echo "PowerOnHours: " & objItem.PowerOnHours
Wscript.Echo "RequestedState: " & objItem.RequestedState
Wscript.Echo "Status: " & objItem.Status
If isNull(objItem.StatusDescriptions) Then
Wscript.Echo "StatusDescriptions: "
Else
Wscript.Echo "StatusDescriptions: " & Join(objItem.StatusDescriptions, ",")
End If
Wscript.Echo "StatusInfo: " & objItem.StatusInfo
Wscript.Echo "SystemCreationClassName: " & objItem.SystemCreationClassName
Wscript.Echo "SystemName: " & objItem.SystemName
Wscript.Echo "TimeOfLastStateChange: " & objItem.TimeOfLastStateChange
Wscript.Echo "TotalPowerOnHours: " & objItem.TotalPowerOnHours
Next
SystemNameをコンピュータ名に変換する必要がある場合には、Msvm_ComputerSystem等を利用して、実施します。
例えばシステム名”FE1AD57E-1A15-4611-BEA0-76A6C5959114″を表示名に変換する場合には以下のように。
Wscript.Echo "Name: " & SystemName2ElementName("FE1AD57E-1A15-4611-BEA0-76A6C5959114")
Function SystemName2ElementName(strSYSTEMNAME)
strComputer = "."
Set objMsvm_ComputerSystem = GetObject("winmgmts:\\" & strComputer & "\root\virtualization")
Set colItems = objMsvm_ComputerSystem.ExecQuery("SELECT * FROM Msvm_ComputerSystem Where Name=" & "'" & strSYSTEMNAME & "'",,48)
For Each objItem in colItems
SystemName2ElementName = objItem.ElementName
Next
End Function
参考URL
関連する記事
- Newer : デフォルトゲートウェイをVBScriptで表示させる方法
- Older : 火の鳥 鳳凰編
Comments:0
Trackbacks:0
- Trackback URL for this entry
- http://pnpk.net/cms/archives/1925/trackback
- Listed below are links to weblogs that reference
- Msvm_HeartbeatComponentをVBScriptで取得する方法 from http://pnpk.net
